Model CW-11 Indicator
Instruction Manual
Indicador Modelo CW-11
Manual De Instrucciones
Indicateur Modèle CW-11
Manuel De L'utilisateur
Vista de pagina 0
1 2 3 4 5 6 ... 36 37

Indice de contenidos

Pagina 1

Model CW-11 IndicatorInstruction ManualIndicador Modelo CW-11Manual De InstruccionesIndicateur Modèle CW-11Manuel De L'utilisateur

Pagina 2

7CW-11 IndicatorNOTICE:The socket/outlet must be installed nearthe equipment and shall be easily accessible.2.5 Cautionary NotesModel CW-1

Pagina 3

8CW-11 Indicator2.6.3 Operating the IndicatorOnce the Indicator and Scale Base are connected and installed, follow the setup procedure outl

Pagina 4 - TABLE OF CONTENTS

9CW-11 IndicatorMAIN MENUCALSEt uP rEAd Print LOCSWCALIBRATIONSPAN YLIN YLegal for TradeON, Off, CanZero2%,18%, 100%Calibration Unitlb or kgFull Sca

Pagina 5 - TABLE OF CONTENTS (Cont.)

10CW-11 Indicator2.8 Initial Setup (Cont.)2.8.3 Load Cell Capacity InformationReview the specifications of the scale base to be used with the Indicato

Pagina 6

11CW-11 Indicator2.8 Initial Setup (Cont.)2.8.4 Setup MenuThe CW-11 Indicator Setup Menu must be entered the first time the Indicator is u

Pagina 7

12CW-11 IndicatorPress G/N/T/MENU, F xx is displayed. This is fullscale capacity selections. xx= value last set.Selections are: 5, 10, 15, 20, 25

Pagina 8 - 2. INSTALLATION

13CW-11 Indicator2.8 Initial Setup (Cont.)2.8.5 Readout MenuThe Readout menu is used to adapt the Indicator to environmental conditions, set mea

Pagina 9

14CW-11 Indicator2.8 Initial Setup (Cont.)2.8.5 Readout Menu (Cont.)ProcedureAVERAGING LEVEL (Cont.)Press G/N/T/MENU button, AL LO is displayed. T

Pagina 10 - CW-11 Indicator

15CW-11 IndicatorUNITS SELECTIONPress G/N/T/MENU button, Un OFF g is displayed.Press PRINT/UNITS button, and select ON or OFF.OFF is the default sett

Pagina 11

16CW-11 IndicatorAUTO ZEROPress G/N/T/MENU button, AZt 0.5 is displayed.This is the Auto Zero Threshold setting. Auto Zerominimizes the effects

Pagina 12

Ohaus Corporation, 19A Chapin Road, P.O. Box 2033 Pine Brook, New Jersey, 07058, USADeclaration of Conformity We, Ohaus Corporation, declare under

Pagina 13

17CW-11 IndicatorLCD BACK LIGHTPress G/N/T/MENU button, bLAutOis displayed. Youcan select to have the LCD backlight either oncontiuously, off or

Pagina 14

18CW-11 Indicator2.8 Initial Scale Setup (Cont.)2.8.6 Print MenuThe Print menu provides data communication settings which can be entered. It co

Pagina 15

19CW-11 IndicatorDATAPress G/N/T/MENU button, dAtA 7 is displayed.This is the data length.Press PRINT/UNITS button, and select desired datalength of

Pagina 16

20CW-11 IndicatorINTERVAL - PRINTING (Cont.)Pressing the TARE button increments the digit from 1to 0. When the desired number of seconds havebeen ent

Pagina 17

21CW-11 IndicatorProcedure (Cont.)With the Indicator ON, press and hold the G/N/T/MENU button until MENU is displayed. When yourelease the G/N/T/MEN

Pagina 18

22CW-11 Indicator3. CALIBRATION AND SEALINGModel CW-11 Indicator requires span calibration before using. Span calibration ensures that the Ind

Pagina 19

23CW-11 IndicatorProcedureLINEARITY CALIBRATIONWith the Indicator ON, press and hold the buttonG/N/T/MENU until MENU is displayed. When yourelease t

Pagina 20

24CW-11 IndicatorProcedureSet up Indicator, and calibrate. After this is done,remove power from the Indicator.At the bottom of the rear cover of th

Pagina 21

25CW-11 IndicatorReplace the battery cover and four battery coverscrews. One of these screws is cross drilled andcan accept a wire seal.NOTICE: Th

Pagina 22

26CW-11 Indicator4. OPERATIONBefore using the Indicator, make sure it has been properly set up and calibrated. Refer to Sections 2 and 3 andreview se

Pagina 23

NOTE: THIS EQUIPMENT HAS BEEN TESTED AND FOUND TO COMPLY WITH THE LIMITS FOR A CLASS A DIGITAL DEVICE, PURSUANT TOPART 15 OF THE FCC RULES.THESE LIMI

Pagina 24

27CW-11 Indicator4. OPERATION (Cont.)4.5 Gross/Net/Tare Recall OperationWhen a container has been placed on the platformand tared, it's wei

Pagina 25 - 3. CALIBRATION AND SEALING

28CW-11 Indicator4. OPERATION (Cont.)4.8 Establishing a New Average Piece Weight(APW)If the APW has not been calculated previously, pro-ceed as foll

Pagina 26

29CW-11 Indicator4. OPERATION (Cont.)4.11 Animal WeighingAnimal weighing is enabled only when 'Ani' in theRead menu under Alternate Mode i

Pagina 27 - Procedure

30CW-11 Indicator4.13 Printing DataPrinting data to an external computer or printer requires that the communications parameters in the Print menu,be

Pagina 28 - PAPER SEAL

31CW-11 Indicator5 CARE AND MAINTENANCETo keep the Indicator operating properly, the housing should be kept clean and free from foreign material. Ifn

Pagina 29 - Brutto

32CW-11 Indicator5 CARE AND MAINTENANCE (Cont.)Cannot display weight in desiredweighing unit.RS232 not working.Unable to calibrate unit.Desired

Pagina 30

33CW-11 Indicator5.2Error Codes ListThe following list describes the various error codes and which can appear on the display and the suggeste

Pagina 31 - 4. OPERATION (Cont.)

34CW-11 IndicatorCapacity (lb or kg) 5 to 20,000*Graduation (readability) lb or kg 0.001 to 5*Displayed Resolution 1:5000 LFT or 1: 20,000 Non LF

Pagina 32

1TABLE OF CONTENTSOVERVIEW OF CONTROLS AND INDICATOR FUNCTIONS ...

Pagina 33

2TABLE OF CONTENTS (Cont.)4.6 Unit Switch Operation ...

Pagina 34 - 5 CARE AND MAINTENANCE

3CW-11 IndicatorCWOVERVIEW OF CONTROLS AND INDICATOR FUNCTIONS No. Designation Function 1 Display LCD display, indicates weight, modes and

Pagina 35

4CW-11 Indicator1. GETTING TO KNOW YOUR INDICATOR1.1IntroductionThank you for deciding to purchase a CW-11 Indicator from Ohaus. The Ohaus CW-11 Indi

Pagina 36

5CW-11 Indicator2.2 Selecting the LocationThe Indicator should be used in an environment which is free from corrosives, vibration or temperatu

Pagina 37 - 5.4 Technical Data (Cont.)

6CW-11 IndicatorJUMP 1JUMP 211+EXE +SEN+SIGCGND -SIG -SEN -EXETXD RXD GNDNEUT 110V 220V131750mA250V1J9 3NEUT 110V 220VJ813T1J71423J6J115J5AJ5B5J215169