Ohaus NBF1A2 Navigator Balances Manual de usuario

Busca en linea o descarga Manual de usuario para Escamas Ohaus NBF1A2 Navigator Balances. Ohaus NBF1A2 Navigator Balances User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 107
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
1
INSTRUCTION MANUAL
Balances
Ohaus CorporationOhaus Corporation
Ohaus CorporationOhaus Corporation
Ohaus Corporation
29 Hanover Road
Florham Park, NJ
07932-0900
Vista de pagina 0
1 2 3 4 5 6 ... 106 107

Indice de contenidos

Pagina 1 - Balances

1INSTRUCTION MANUALBalancesOhaus CorporationOhaus CorporationOhaus CorporationOhaus CorporationOhaus Corporation29 Hanover RoadFlorham Park, NJ07932-0

Pagina 2

102.5 Connecting Power and CommunicationsAC Power OperationConnect the cord from the AC Adapter supplied to theconnector located at the rear of th

Pagina 3

1INSTALLATION INSTRUCTIONS FOR DUNKIN DONUTSCOFFEE-BY-THE-POUND SCALEKIT NDF1A2-DAOThese instructions pertain to the Ohaus Navigator Scale, Part Numbe

Pagina 4 - TABLE OF CONTENTS

2Installing the Auxiliary Display to the Coffee Grinder1. Remove the (2) screws located on top of the grinder as shown in Figure 2.2. Place the Auxill

Pagina 5 - TABLE OF CONTENTS (Cont.)

3 Capacity x Readability 6100 x 1 gram13.45 x 0.01 pound215 x 0.1 ounce Weighing units g, lbs, oz* Weighing modes Weighing, Checkweighing * Option

Pagina 6 - OVERVIEW OF CONTROLS

4State Weights and Measures DirectorsAlabamaGuamSteadman L. HollisMichael KuhlmannDirector Wghts & Meas DivDirectorAL Dept of Agr & IndustryGU

Pagina 7

5Page 4MichiganNevadaPatrick MercerEdward M. HogansonDir Motor Fuel Qual Wghts&MeasSupervisor Weights & MeasuresMI Dept of AgricultureNV Dept

Pagina 8

6Page 5UtahKyle R. StephensDir Regulatory Services DivUT Dept of Agriculture & FoodPO Box 146500Salt Lake City, UT 84114-6500Telephone: 801-538-

Pagina 11 - 3 OPERATING YOUR BALANCE

11 RS232Power ON/OFF (Battery mode only)Baud 300, 1200, 2400, 4800, 9600Parity None, -E-, -Odd-, -0-, -1-Data 7,8Stop 1, 2Lock ON/OFFE

Pagina 12 - 3.3 Calibration

123.2 Turning On the BalanceThe balance is ready to operate after the installation procedures are performed. When the balance is first turned onand

Pagina 13 - Calibration Masses

13CALIBRATION MASSES LINEARITY SPAN ONLY CAPACITY MASSES MASSES 32g

Pagina 14 - Procedure

143.3.1 Internal Calibration (InCALTM)On NavigatorTM balances equipped with the InCalTM feature, calibration can be accomplished using the internal ca

Pagina 15 - 3.3.2 Calibration Message

153.3.2 Calibration MessageOn NavigatorTM balances equipped with the InCalTM feature, a screen prompt of CAL NOW appears when the balancerequires cali

Pagina 16 - 3.3.3 Calibration Adjust

163.3.3 Calibration AdjustBalances with InCalTM contain software which allows theinternal calibration value to be adjusted by + 100 divisionsat full s

Pagina 17 - 3.3.4 Span Calibration

173.3.4 Span CalibrationSpan calibration utilizes two calibration points, one at zero and a choice of either half capacity or full capacity. Allbalan

Pagina 18 - 3.3.5 User Calibration

183.3.5 User CalibrationUser calibration is used when it is desired to calibrate the balance using a mass of known value. User calibration limitsare n

Pagina 19 - 3.3.6 Linearity Calibration

19Procedure• Clear the pan.• Press the Setup button, CAL is displayed.• Press Enter button, CAL TYP is displayed.• Press Enter button.• Press bu

Pagina 20 - 3.3.7 Calibration Test

2IEC1010-1 & EN60950:1992 Safety RegulationsIEC1010-1 & EN60950:1992 SicherheitsbestimmungenIEC1010-1 & EN60950:1992 Consignes de sécurité

Pagina 21 - User Calibration Printout

203.3.7 Calibration TestCalibration test feature allows a check of a known calibration mass against the last stored calibration information in thebala

Pagina 22 - Zero/Tare

213.3.8 Calibration GLP PrintoutIf any option in the GLP Set Menu is turned On, GLP automatically prints data after calibration is completed. - - -

Pagina 23 - 3.5 Percent Weighing

223.4 WeighingNavigatorTM balances are shipped with grams only enabled. When the balance is to be used with other units of mea-sure, the desired unit

Pagina 24 - 3.6Parts Counting

233.5 Percent WeighingPercent Weighing is enabled only when Percent is turned ON in the Mode menu under Setup. Percent weighingpermits you to place a

Pagina 25 - 3.7 Animal Weighing

243.6Parts CountingParts Counting is enabled only when Count is turned ON in the Mode menu under Setup. In the parts countingmode, the balance displ

Pagina 26 - 3.8 Checkweighing

25Procedure• Press the Mode button.• Press button until ANIMAL is displayed.• Press Enter button to continue, LEVEL is displayed.• Press or but

Pagina 27 - 3.9 Printing Data

26Procedure• Press the Mode button.• Press button until CHECK is displayed.• Press Enter button to continue, NOM WT is dis -played. The numerical d

Pagina 28

273.9 Printing DataPrinting data to an external computer or printer requires that the communications parameters in the Setup menu, printoptions and c

Pagina 29

284. SETTING UP YOUR BALANCE4.1 Setting Date and TimeYour NavigatorTM balance provides date and time data which can be viewed on a computer or printed

Pagina 30

294.2ReadoutThe Readout menu is used to adapt the balance to environmental conditions. It contains four menus: Stable, Auto 0,Filter, Lock and Exit.

Pagina 31

3ISO 9001 Certificate for Ohaus Corporation. Ohaus Corporation, USA, was examined and evaluated in 1994 by the Bureau Veritas Quality International,B

Pagina 32 - GLP Continuously

304.3 Good Laboratory Practices (GLP) DataThe GLP Data menu enables the storage of a user identification number (6 digits) and/or a project number (6

Pagina 33

314.5 PrintThe Print menu provides a number of options which can be turned ON or OFF. It contains eight menus: Auto Print,feature which includes selec

Pagina 34

32GLP Once After TareWhen the GLP Tare function is set ON, it allows the balance to output the GLP selections and weight measurementonce after tare.

Pagina 35 - all menus

334.6 RS232The RS232 menu provides communication parameters which can be set to accommodate external printers or comput-ers. It contains six menus: P

Pagina 36 - Global Reset

344.7 ModeThe Mode menu permits the selection of five modes which can be turned ON or OFF. These modes are: Weigh,Percent, Count, Animal Weighing, Ch

Pagina 37 - 4.10 Custom Unit

354.8 UnitsThe Units menu permits the selection of the measuring units which can be turned ON or OFF and locked.Procedure• Press the Setup button.• Pr

Pagina 38 - Procedure (Cont.)

36LFT is OffMode MenuWEIGH= OnPERCENT= OffCOUNT= OffANIMAL= OffLock Switch is OffMenu LocksRS232= OffREADOUT= OffGLPSET= OffMODE= OffUNITS= Of

Pagina 39 - 4.11 Auto Shut-Off

374.10 Custom UnitCustom Unit is enabled when Custom Unit Setup under Units Menu is turned ON. This feature can be used to createyour own custom weig

Pagina 40 - 4.13 Weigh Below

38LSD’sLSD .5 Adds one decimalplace display countsby 5’s.LSD 1 Display counts by1’s.LSD 2 Display counts by 2’s.LSD 5 Display counts by 5’s.LSD 10 Dis

Pagina 41 - 5.1 Troubleshooting

394.11 Auto Shut-OffAn energy saver is incorporated in the balance to prolong battery life and to conserve ac power. A built-in timer in thebalance c

Pagina 42 - RS232 Commands

4TABLE OF CONTENTSOVERVIEW OF CONTROLS ...

Pagina 43 - Character Description

404.12 Menu Lock-Out ProtectionAccess to the various menus can be disabled by setting the Lock Switch located on the printed circuit board inside ofth

Pagina 44

41PROBABLE CAUSE(S)Power cord not plugged in or properlyconnected to balance.Balance was not re-zeroed beforeweighing.Balance not properly calibrated.

Pagina 45

42CommandCharacter Description? Print current modennnnA Set Auto Print feature to “nnnn”(see table).RS232 COMMAND TABLEField: Mode Stab CR LFLength: 5

Pagina 46 - 5.7 Accessories

43RS232 COMMAND TABLE (Cont.)0 = minimum level1=2=3 = maximum level1 = milligrams2 = grams3 = kilo grams4 = dwt5 = Carats6 = Ounces7 = Ounces troy8 =

Pagina 47 - 5.8 Specifications

44CommandCharacter DescriptionxZ Set Auto Zero to “x”,where x = 0 to 3 ). 0=Off, 1=0.5d, 2=1d, 3=5d.x% Set % reference function. Uses x (Real Number)

Pagina 48 - LIMITED WARRANTY

455.3 Error Codes ListError Codes ListThe following list describes the various error codes which can appear on the display and the suggested remedy.Da

Pagina 49

465.5 Service InformationIf the Troubleshooting section does not resolve or describe your problem, you will need to contact an authorized OhausService

Pagina 50

475.8 SpecificationsCapacity 32 210 410 810 2100 4100 8100Readability 0.002g 0.01g 0.01g 0.01g

Pagina 51

48LIMITED WARRANTYOhaus products are warranted against defects in materials and workmanship from the date of deliv-ery through the duration of the war

Pagina 52

49Ohaus Corporation29 Hanover Road,Florham Park, NJ 07932, USATel: (973) 377-9000,Fax: (973) 593-0359With offices worldwide.© Ohaus Corporation 1999,

Pagina 53

5TABLE OF CONTENTS (Cont.)4.3 Good Laboratory Practices (GLP) Data...

Pagina 54

1INSTALLATION INSTRUCTIONS FOR DUNKIN DONUTSCOFFEE-BY-THE-POUND SCALEKIT NDF1A2-DAOThese instructions pertain to the Ohaus Navigator Scale, Part Numbe

Pagina 55

2Installing the Auxiliary Display to the Coffee Grinder1. Remove the (2) screws located on top of the grinder as shown in Figure 2.2. Place the Auxill

Pagina 56

3 Capacity x Readability 6100 x 1 gram13.45 x 0.01 pound215 x 0.1 ounce Weighing units g, lbs, oz* Weighing modes Weighing, Checkweighing * Option

Pagina 57

4State Weights and Measures DirectorsAlabamaGuamSteadman L. HollisMichael KuhlmannDirector Wghts & Meas DivDirectorAL Dept of Agr & IndustryGU

Pagina 58 - Type Approved Models

5Page 4MichiganNevadaPatrick MercerEdward M. HogansonDir Motor Fuel Qual Wghts&MeasSupervisor Weights & MeasuresMI Dept of AgricultureNV Dept

Pagina 59

6Page 5UtahKyle R. StephensDir Regulatory Services DivUT Dept of Agriculture & FoodPO Box 146500Salt Lake City, UT 84114-6500Telephone: 801-538-

Pagina 62

Ohaus CorporationOhaus CorporationOhaus CorporationOhaus CorporationOhaus Corporation29 Hanover RoadFlorham Park, NJ07932-0900INSTRUCTION MANUALBalanc

Pagina 64

6OVERVIEW OF CONTROLS 1 3 4 256 8910 7 No. Designation Function 1 I On/Off button Power on/off button. 2 Mode button Selects standard

Pagina 65 - lbozcti

iIEC1010-1 & EN60950:1992 Safety RegulationsIEC1010-1 & EN60950:1992 SicherheitsbestimmungenIEC1010-1 & EN60950:1992 Consignes de sécurité

Pagina 66 - 2. INSTALLATION

iiISO 9001 Certificate for Ohaus Corporation. Ohaus Corporation, USA, was examined and evaluated in 1994 by the BureauVeritas Quality International,

Pagina 67 - 2.3 Installing Wind Shield

iiiTABLE OF CONTENTSTABLE OF CONTENTSTABLE OF CONTENTSTABLE OF CONTENTSTABLE OF CONTENTSOVERVIEW OF CONTROLS ...

Pagina 68 - COMPARTMENT

ivTABLE OF CONTENTS (Cont.)TABLE OF CONTENTS (Cont.)TABLE OF CONTENTS (Cont.)TABLE OF CONTENTS (Cont.)TABLE OF CONTENTS (Cont.)4.3 Good Laboratory Pra

Pagina 69

1TM®PrintModeSetupUnitsTMEnterOn/OffG/N/TZeroTareOVERVIEW OF CONTROLS 1 3 4 256 8910 7 No. Designation Function 1 I On/Off button Power

Pagina 70 - • Linearity

Stable Mode UnitsSetupCustomUse keys to change,B/GNETCenterof Zero PC GN lbozctipress Entermg kgChange %dwtOVERVIEW OF DISPLAY INDICATOR

Pagina 71 - g

3TM1. GETTING TO KNOW YOUR BALANCEPlease read through this section carefully, as it contains important information for safe and economical operation o

Pagina 72

4TMDO NOT install the balance:• Next to open windows or doors causing drafts orrapid temperature changes.• Near air conditioning or heat vents.• Near

Pagina 73

5TM2.5 Connecting Power and CommunicationsNOTE: If the balance is to be used in a legal for tradeapplication in Canada, install the four nuts prov

Pagina 74

6TM RS232Power ON/OFF (Battery mode only)Baud 300, 1200, 2400, 4800, 9600Parity None, -E-, -Odd-, -0-, -1-Data 7,8Stop 1, 2Lock ON/OFF

Pagina 75

OVERVIEW OF DISPLAY INDICATORS No. Function12356789101213414 No. Function 1 Use (Pointer Group) key to change - used toprompt the user w

Pagina 76 - 3.6 Parts Counting

7TM3.2 Turning On the BalanceThe balance is ready to operate after the installation procedures are performed. When the balance is first turned onand

Pagina 77 - 3.7 Checkweighing

8TM®PrintModeSetupUnitsTMEnterOn/OffG/N/TZeroTare®PrintModeSetupUnitsTMEnterOn/OffG/N/TZeroTare3.3.1 Span CalibrationSpan calibration utilizes two cal

Pagina 78 - 429.5 g B/G

9TM®PrintModeSetupUnitsTMEnterOn/OffG/N/TZeroTare®PrintModeSetupUnitsTMEnterOn/OffG/N/TZeroTareProcedure• Clear the pan.• Press the Setup button, CAL

Pagina 79

10TM3.3.3 Calibration GLP PrintoutIf any option in the GLP Set Menu is turned On, GLP automatically prints data after calibration is completed. - -

Pagina 80 - 4.2 Readout

11TM®PrintModeSetupUnitsTMEnterOn/OffG/N/TZeroTare3.4 WeighingNavigatorTM balances are shipped with certain commonly used units of measure enabled. W

Pagina 81

12TM®PrintModeSetupUnitsTMEnterOn/OffG/N/TZeroTare3.5 Percent WeighingPercent Weighing is enabled only when Percent is turned ON in the Mode menu unde

Pagina 82 - Print Numeric Data Only

13TM®PrintModeSetupUnitsTMEnterOn/OffG/N/TZeroTare®PrintModeSetupUnitsTMEnterOn/OffG/N/TZeroTare3.6 Parts CountingParts Counting is enabled only when

Pagina 83

14TM®PrintModeSetupUnitsTMEnterOn/OffG/N/TZeroTareProcedure• Press the Mode button.• Press button until CHECK is displayed.• Press Enter button to c

Pagina 84

15TM®PrintModeSetupUnitsTMEnterOn/OffG/N/TZeroTare3.8 Printing DataPrinting data to an external computer or printer requires that the communications

Pagina 85

16TM®PrintModeSetupUnitsTMEnterOn/OffG/N/TZeroTare®PrintModeSetupUnitsTMEnterOn/OffG/N/TZeroTare4. SETTING UP YOUR BALANCE4.1 Setting Date and TimeYou

Pagina 86 - Capacity:

8••••• Pan 3" Diameter •••••• Pan Support, round 3" •••••• Pan 4.75 Diameter • •••••• Pan Support, round 4.75"

Pagina 87

17TM®PrintModeSetupUnitsTMEnterOn/OffG/N/TZeroTare4.2 ReadoutThe Readout menu is used to adapt the balance to environmental conditions. It contains t

Pagina 88 - 4.10 Auto Shut-Off

18TM®PrintModeSetupUnitsTMEnterOn/OffG/N/TZeroTare®PrintModeSetupUnitsTMEnterOn/OffG/N/TZeroTare4.3 Good Laboratory Practices (GLP) DataThe GLP Data m

Pagina 89 - 4.11 Menu Lock-Out Protection

19TM®PrintModeSetupUnitsTMEnterOn/OffG/N/TZeroTare4.5 PrintThe Print menu provides a number of options which can be turned ON or OFF. It contains seve

Pagina 90

20TMGLP Once After TareWhen the GLP Tare function is set ON, it allows the balance to output the GLP selections and weight measurementonce after tare.

Pagina 91

21TM®PrintModeSetupUnitsTMEnterOn/OffG/N/TZeroTare4.6 RS232The RS232 menu provides communication parameters which can be set to accommodate external p

Pagina 92 - 5.2 RS232 Interface

22TM®PrintModeSetupUnitsTMEnterOn/OffG/N/TZeroTare4.7 ModeThe Mode menu permits the selection of four modes which can be turned ON or OFF. These mode

Pagina 93 - Character Description

23TM®PrintModeSetupUnitsTMEnterOn/OffG/N/TZeroTare4.8 UnitsThe Units menu permits the selection of the measuring units which can be turned ON or OFF.P

Pagina 94

24TM®PrintModeSetupUnitsTMEnterOn/OffG/N/TZeroTareProcedure• Press the Setup button.• Press button until GLOBAL is displayed.• Press Enter button to

Pagina 95

25TM®PrintModeSetupUnitsTMEnterOn/OffG/N/TZeroTare4.10 Auto Shut-OffAn energy saver is incorporated in the balance to prolong battery life and to cons

Pagina 96

26TM4.11 Menu Lock-Out ProtectionAccess to the various menus can be disabled by setting the Lock Switch located on the printed circuit board inside of

Pagina 97

9DO NOT install the balance:• Next to open windows or doors causing drafts orrapid temperature changes.• Near air conditioning or heat vents.• Near vi

Pagina 98

27TM4.13 Weigh BelowA weigh below hook is located at the bottom of the balance. To use this feature, remove power from the balance andremove the prot

Pagina 99

28TMPROBABLE CAUSE(S)Power cord not plugged in or properlyconnected to balance.Balance was not re-zeroed beforeweighing.Balance not properly calibrate

Pagina 100 - KIT NDF1A2-DAO

29TMRS232 COMMAND TABLE5.2 RS232 InterfaceNavigatorTM balances are equipped with a bi-directionalRS232 compatible interface for communication withprin

Pagina 101

30TMRS232 COMMAND TABLE (Cont.)CommandCharacter DescriptionCN Print Checkweighing nominal weight.CO Print Checkweighing over limit.CU Print Checkweig

Pagina 102

31TMRS232 COMMAND TABLE (Cont.)CommandCharacter Descriptionx% Set % reference function. Uses x (Real Number) as current PercentReference. * Referen

Pagina 103

32TM5.3 Error Codes ListError Codes ListThe following list describes the various error codes which can appear on the display and the suggested remedy.

Pagina 104

33TM5.5 Service InformationIf the Troubleshooting section does not resolve or describe your problem, you will need to contact an authorizedOhaus Servi

Pagina 105

34TM5.8 SpecificationsCapacity 610g 6100gAccuracy Class III III III III III III III

Pagina 107

Ohaus Corporation29 Hanover Road,Florham Park, NJ 07932, USATel: (973) 377-9000,Fax: (973) 593-0359With offices worldwide.© Ohaus Corporation 2000, a

Comentarios a estos manuales