1INSTRUCTION MANUALBalancesOhaus CorporationOhaus CorporationOhaus CorporationOhaus CorporationOhaus Corporation29 Hanover RoadFlorham Park, NJ07932-0
102.5 Connecting Power and CommunicationsAC Power OperationConnect the cord from the AC Adapter supplied to theconnector located at the rear of th
1INSTALLATION INSTRUCTIONS FOR DUNKIN DONUTSCOFFEE-BY-THE-POUND SCALEKIT NDF1A2-DAOThese instructions pertain to the Ohaus Navigator Scale, Part Numbe
2Installing the Auxiliary Display to the Coffee Grinder1. Remove the (2) screws located on top of the grinder as shown in Figure 2.2. Place the Auxill
3 Capacity x Readability 6100 x 1 gram13.45 x 0.01 pound215 x 0.1 ounce Weighing units g, lbs, oz* Weighing modes Weighing, Checkweighing * Option
4State Weights and Measures DirectorsAlabamaGuamSteadman L. HollisMichael KuhlmannDirector Wghts & Meas DivDirectorAL Dept of Agr & IndustryGU
5Page 4MichiganNevadaPatrick MercerEdward M. HogansonDir Motor Fuel Qual Wghts&MeasSupervisor Weights & MeasuresMI Dept of AgricultureNV Dept
6Page 5UtahKyle R. StephensDir Regulatory Services DivUT Dept of Agriculture & FoodPO Box 146500Salt Lake City, UT 84114-6500Telephone: 801-538-
7
11 RS232Power ON/OFF (Battery mode only)Baud 300, 1200, 2400, 4800, 9600Parity None, -E-, -Odd-, -0-, -1-Data 7,8Stop 1, 2Lock ON/OFFE
123.2 Turning On the BalanceThe balance is ready to operate after the installation procedures are performed. When the balance is first turned onand
13CALIBRATION MASSES LINEARITY SPAN ONLY CAPACITY MASSES MASSES 32g
143.3.1 Internal Calibration (InCALTM)On NavigatorTM balances equipped with the InCalTM feature, calibration can be accomplished using the internal ca
153.3.2 Calibration MessageOn NavigatorTM balances equipped with the InCalTM feature, a screen prompt of CAL NOW appears when the balancerequires cali
163.3.3 Calibration AdjustBalances with InCalTM contain software which allows theinternal calibration value to be adjusted by + 100 divisionsat full s
173.3.4 Span CalibrationSpan calibration utilizes two calibration points, one at zero and a choice of either half capacity or full capacity. Allbalan
183.3.5 User CalibrationUser calibration is used when it is desired to calibrate the balance using a mass of known value. User calibration limitsare n
19Procedure• Clear the pan.• Press the Setup button, CAL is displayed.• Press Enter button, CAL TYP is displayed.• Press Enter button.• Press bu
2IEC1010-1 & EN60950:1992 Safety RegulationsIEC1010-1 & EN60950:1992 SicherheitsbestimmungenIEC1010-1 & EN60950:1992 Consignes de sécurité
203.3.7 Calibration TestCalibration test feature allows a check of a known calibration mass against the last stored calibration information in thebala
213.3.8 Calibration GLP PrintoutIf any option in the GLP Set Menu is turned On, GLP automatically prints data after calibration is completed. - - -
223.4 WeighingNavigatorTM balances are shipped with grams only enabled. When the balance is to be used with other units of mea-sure, the desired unit
233.5 Percent WeighingPercent Weighing is enabled only when Percent is turned ON in the Mode menu under Setup. Percent weighingpermits you to place a
243.6Parts CountingParts Counting is enabled only when Count is turned ON in the Mode menu under Setup. In the parts countingmode, the balance displ
25Procedure• Press the Mode button.• Press button until ANIMAL is displayed.• Press Enter button to continue, LEVEL is displayed.• Press or but
26Procedure• Press the Mode button.• Press button until CHECK is displayed.• Press Enter button to continue, NOM WT is dis -played. The numerical d
273.9 Printing DataPrinting data to an external computer or printer requires that the communications parameters in the Setup menu, printoptions and c
284. SETTING UP YOUR BALANCE4.1 Setting Date and TimeYour NavigatorTM balance provides date and time data which can be viewed on a computer or printed
294.2ReadoutThe Readout menu is used to adapt the balance to environmental conditions. It contains four menus: Stable, Auto 0,Filter, Lock and Exit.
3ISO 9001 Certificate for Ohaus Corporation. Ohaus Corporation, USA, was examined and evaluated in 1994 by the Bureau Veritas Quality International,B
304.3 Good Laboratory Practices (GLP) DataThe GLP Data menu enables the storage of a user identification number (6 digits) and/or a project number (6
314.5 PrintThe Print menu provides a number of options which can be turned ON or OFF. It contains eight menus: Auto Print,feature which includes selec
32GLP Once After TareWhen the GLP Tare function is set ON, it allows the balance to output the GLP selections and weight measurementonce after tare.
334.6 RS232The RS232 menu provides communication parameters which can be set to accommodate external printers or comput-ers. It contains six menus: P
344.7 ModeThe Mode menu permits the selection of five modes which can be turned ON or OFF. These modes are: Weigh,Percent, Count, Animal Weighing, Ch
354.8 UnitsThe Units menu permits the selection of the measuring units which can be turned ON or OFF and locked.Procedure• Press the Setup button.• Pr
36LFT is OffMode MenuWEIGH= OnPERCENT= OffCOUNT= OffANIMAL= OffLock Switch is OffMenu LocksRS232= OffREADOUT= OffGLPSET= OffMODE= OffUNITS= Of
374.10 Custom UnitCustom Unit is enabled when Custom Unit Setup under Units Menu is turned ON. This feature can be used to createyour own custom weig
38LSD’sLSD .5 Adds one decimalplace display countsby 5’s.LSD 1 Display counts by1’s.LSD 2 Display counts by 2’s.LSD 5 Display counts by 5’s.LSD 10 Dis
394.11 Auto Shut-OffAn energy saver is incorporated in the balance to prolong battery life and to conserve ac power. A built-in timer in thebalance c
4TABLE OF CONTENTSOVERVIEW OF CONTROLS ...
404.12 Menu Lock-Out ProtectionAccess to the various menus can be disabled by setting the Lock Switch located on the printed circuit board inside ofth
41PROBABLE CAUSE(S)Power cord not plugged in or properlyconnected to balance.Balance was not re-zeroed beforeweighing.Balance not properly calibrated.
42CommandCharacter Description? Print current modennnnA Set Auto Print feature to “nnnn”(see table).RS232 COMMAND TABLEField: Mode Stab CR LFLength: 5
43RS232 COMMAND TABLE (Cont.)0 = minimum level1=2=3 = maximum level1 = milligrams2 = grams3 = kilo grams4 = dwt5 = Carats6 = Ounces7 = Ounces troy8 =
44CommandCharacter DescriptionxZ Set Auto Zero to “x”,where x = 0 to 3 ). 0=Off, 1=0.5d, 2=1d, 3=5d.x% Set % reference function. Uses x (Real Number)
455.3 Error Codes ListError Codes ListThe following list describes the various error codes which can appear on the display and the suggested remedy.Da
465.5 Service InformationIf the Troubleshooting section does not resolve or describe your problem, you will need to contact an authorized OhausService
475.8 SpecificationsCapacity 32 210 410 810 2100 4100 8100Readability 0.002g 0.01g 0.01g 0.01g
48LIMITED WARRANTYOhaus products are warranted against defects in materials and workmanship from the date of deliv-ery through the duration of the war
49Ohaus Corporation29 Hanover Road,Florham Park, NJ 07932, USATel: (973) 377-9000,Fax: (973) 593-0359With offices worldwide.© Ohaus Corporation 1999,
5TABLE OF CONTENTS (Cont.)4.3 Good Laboratory Practices (GLP) Data...
1INSTALLATION INSTRUCTIONS FOR DUNKIN DONUTSCOFFEE-BY-THE-POUND SCALEKIT NDF1A2-DAOThese instructions pertain to the Ohaus Navigator Scale, Part Numbe
2Installing the Auxiliary Display to the Coffee Grinder1. Remove the (2) screws located on top of the grinder as shown in Figure 2.2. Place the Auxill
3 Capacity x Readability 6100 x 1 gram13.45 x 0.01 pound215 x 0.1 ounce Weighing units g, lbs, oz* Weighing modes Weighing, Checkweighing * Option
4State Weights and Measures DirectorsAlabamaGuamSteadman L. HollisMichael KuhlmannDirector Wghts & Meas DivDirectorAL Dept of Agr & IndustryGU
5Page 4MichiganNevadaPatrick MercerEdward M. HogansonDir Motor Fuel Qual Wghts&MeasSupervisor Weights & MeasuresMI Dept of AgricultureNV Dept
6Page 5UtahKyle R. StephensDir Regulatory Services DivUT Dept of Agriculture & FoodPO Box 146500Salt Lake City, UT 84114-6500Telephone: 801-538-
Ohaus CorporationOhaus CorporationOhaus CorporationOhaus CorporationOhaus Corporation29 Hanover RoadFlorham Park, NJ07932-0900INSTRUCTION MANUALBalanc
6OVERVIEW OF CONTROLS 1 3 4 256 8910 7 No. Designation Function 1 I On/Off button Power on/off button. 2 Mode button Selects standard
iIEC1010-1 & EN60950:1992 Safety RegulationsIEC1010-1 & EN60950:1992 SicherheitsbestimmungenIEC1010-1 & EN60950:1992 Consignes de sécurité
iiISO 9001 Certificate for Ohaus Corporation. Ohaus Corporation, USA, was examined and evaluated in 1994 by the BureauVeritas Quality International,
iiiTABLE OF CONTENTSTABLE OF CONTENTSTABLE OF CONTENTSTABLE OF CONTENTSTABLE OF CONTENTSOVERVIEW OF CONTROLS ...
ivTABLE OF CONTENTS (Cont.)TABLE OF CONTENTS (Cont.)TABLE OF CONTENTS (Cont.)TABLE OF CONTENTS (Cont.)TABLE OF CONTENTS (Cont.)4.3 Good Laboratory Pra
1TM®PrintModeSetupUnitsTMEnterOn/OffG/N/TZeroTareOVERVIEW OF CONTROLS 1 3 4 256 8910 7 No. Designation Function 1 I On/Off button Power
Stable Mode UnitsSetupCustomUse keys to change,B/GNETCenterof Zero PC GN lbozctipress Entermg kgChange %dwtOVERVIEW OF DISPLAY INDICATOR
3TM1. GETTING TO KNOW YOUR BALANCEPlease read through this section carefully, as it contains important information for safe and economical operation o
4TMDO NOT install the balance:• Next to open windows or doors causing drafts orrapid temperature changes.• Near air conditioning or heat vents.• Near
5TM2.5 Connecting Power and CommunicationsNOTE: If the balance is to be used in a legal for tradeapplication in Canada, install the four nuts prov
6TM RS232Power ON/OFF (Battery mode only)Baud 300, 1200, 2400, 4800, 9600Parity None, -E-, -Odd-, -0-, -1-Data 7,8Stop 1, 2Lock ON/OFF
OVERVIEW OF DISPLAY INDICATORS No. Function12356789101213414 No. Function 1 Use (Pointer Group) key to change - used toprompt the user w
7TM3.2 Turning On the BalanceThe balance is ready to operate after the installation procedures are performed. When the balance is first turned onand
8TM®PrintModeSetupUnitsTMEnterOn/OffG/N/TZeroTare®PrintModeSetupUnitsTMEnterOn/OffG/N/TZeroTare3.3.1 Span CalibrationSpan calibration utilizes two cal
9TM®PrintModeSetupUnitsTMEnterOn/OffG/N/TZeroTare®PrintModeSetupUnitsTMEnterOn/OffG/N/TZeroTareProcedure• Clear the pan.• Press the Setup button, CAL
10TM3.3.3 Calibration GLP PrintoutIf any option in the GLP Set Menu is turned On, GLP automatically prints data after calibration is completed. - -
11TM®PrintModeSetupUnitsTMEnterOn/OffG/N/TZeroTare3.4 WeighingNavigatorTM balances are shipped with certain commonly used units of measure enabled. W
12TM®PrintModeSetupUnitsTMEnterOn/OffG/N/TZeroTare3.5 Percent WeighingPercent Weighing is enabled only when Percent is turned ON in the Mode menu unde
13TM®PrintModeSetupUnitsTMEnterOn/OffG/N/TZeroTare®PrintModeSetupUnitsTMEnterOn/OffG/N/TZeroTare3.6 Parts CountingParts Counting is enabled only when
14TM®PrintModeSetupUnitsTMEnterOn/OffG/N/TZeroTareProcedure• Press the Mode button.• Press button until CHECK is displayed.• Press Enter button to c
15TM®PrintModeSetupUnitsTMEnterOn/OffG/N/TZeroTare3.8 Printing DataPrinting data to an external computer or printer requires that the communications
16TM®PrintModeSetupUnitsTMEnterOn/OffG/N/TZeroTare®PrintModeSetupUnitsTMEnterOn/OffG/N/TZeroTare4. SETTING UP YOUR BALANCE4.1 Setting Date and TimeYou
8••••• Pan 3" Diameter •••••• Pan Support, round 3" •••••• Pan 4.75 Diameter • •••••• Pan Support, round 4.75"
17TM®PrintModeSetupUnitsTMEnterOn/OffG/N/TZeroTare4.2 ReadoutThe Readout menu is used to adapt the balance to environmental conditions. It contains t
18TM®PrintModeSetupUnitsTMEnterOn/OffG/N/TZeroTare®PrintModeSetupUnitsTMEnterOn/OffG/N/TZeroTare4.3 Good Laboratory Practices (GLP) DataThe GLP Data m
19TM®PrintModeSetupUnitsTMEnterOn/OffG/N/TZeroTare4.5 PrintThe Print menu provides a number of options which can be turned ON or OFF. It contains seve
20TMGLP Once After TareWhen the GLP Tare function is set ON, it allows the balance to output the GLP selections and weight measurementonce after tare.
21TM®PrintModeSetupUnitsTMEnterOn/OffG/N/TZeroTare4.6 RS232The RS232 menu provides communication parameters which can be set to accommodate external p
22TM®PrintModeSetupUnitsTMEnterOn/OffG/N/TZeroTare4.7 ModeThe Mode menu permits the selection of four modes which can be turned ON or OFF. These mode
23TM®PrintModeSetupUnitsTMEnterOn/OffG/N/TZeroTare4.8 UnitsThe Units menu permits the selection of the measuring units which can be turned ON or OFF.P
24TM®PrintModeSetupUnitsTMEnterOn/OffG/N/TZeroTareProcedure• Press the Setup button.• Press button until GLOBAL is displayed.• Press Enter button to
25TM®PrintModeSetupUnitsTMEnterOn/OffG/N/TZeroTare4.10 Auto Shut-OffAn energy saver is incorporated in the balance to prolong battery life and to cons
26TM4.11 Menu Lock-Out ProtectionAccess to the various menus can be disabled by setting the Lock Switch located on the printed circuit board inside of
9DO NOT install the balance:• Next to open windows or doors causing drafts orrapid temperature changes.• Near air conditioning or heat vents.• Near vi
27TM4.13 Weigh BelowA weigh below hook is located at the bottom of the balance. To use this feature, remove power from the balance andremove the prot
28TMPROBABLE CAUSE(S)Power cord not plugged in or properlyconnected to balance.Balance was not re-zeroed beforeweighing.Balance not properly calibrate
29TMRS232 COMMAND TABLE5.2 RS232 InterfaceNavigatorTM balances are equipped with a bi-directionalRS232 compatible interface for communication withprin
30TMRS232 COMMAND TABLE (Cont.)CommandCharacter DescriptionCN Print Checkweighing nominal weight.CO Print Checkweighing over limit.CU Print Checkweig
31TMRS232 COMMAND TABLE (Cont.)CommandCharacter Descriptionx% Set % reference function. Uses x (Real Number) as current PercentReference. * Referen
32TM5.3 Error Codes ListError Codes ListThe following list describes the various error codes which can appear on the display and the suggested remedy.
33TM5.5 Service InformationIf the Troubleshooting section does not resolve or describe your problem, you will need to contact an authorizedOhaus Servi
34TM5.8 SpecificationsCapacity 610g 6100gAccuracy Class III III III III III III III
Ohaus Corporation29 Hanover Road,Florham Park, NJ 07932, USATel: (973) 377-9000,Fax: (973) 593-0359With offices worldwide.© Ohaus Corporation 2000, a
Comentarios a estos manuales